DM-HSD-GU141-IAQI2 • Dubai Municipality

Every building in Dubai now has an air quality score.

Federal Law No. 5 of 2025 and Dubai Municipality Guideline DM-HSD-GU141-IAQI2 require every commercial building to continuously monitor indoor air quality, calculate an Environmental Indoor Air Quality Index, and submit compliance reports. Non-compliance carries fines up to AED 100,000 and license revocation.

Built to the exact specification of Dubai Municipality's EIAQI standard.

EIAQI ASSESSMENT

تقييم EIAQI

LIVE
0
Unhealthy for Sensitive Groups
غير صحي للمجموعات الحساسة
DominantPM₂.₅ at 42 µg/m³
StatusAction Required

DM-HSD-GU141-IAQI2 Compliant Report

0

DM-mandated parameters monitored in real time

0

EIAQI categories, exact Table 5 thresholds

0s

Live dashboard refresh interval

0

Languages — full English & Arabic with RTL

The Regulation is Here. The Clock is Ticking.

On March 10, 2026, Dubai enacted Law No. 3 on Quality and Safety of Buildings, requiring mandatory Quality and Safety Certificates for every building with continuous operational oversight. Combined with Federal Law No. 5 of 2025, building owners now face the most comprehensive indoor air quality mandate in the region.

+0 درهم
Maximum fine per violation

Escalating penalties for repeated non-remediation under Law No. 3 of 2026

License Revocation
For persistent non-compliance

Dubai Municipality can revoke building permits and commercial licenses

All Buildings
Including Free Zones

Every commercial, educational, residential, and industrial building in Dubai (hospitals excluded)

Buildings must implement continuous IoT monitoring, calculate EIAQI scores per DM-HSD-GU141-IAQI2, maintain tamper-proof audit trails, store data for 5 years, and submit compliance reports to Dubai Municipality on demand.

Understanding Your EIAQI Score

The Environmental Indoor Air Quality Index converts raw sensor data into a single compliance score from 0 to 500.

0-50
51-100
101-150
151-200
201-300
301-500
جيد
مقبول
غير صحي للفئات الحساسة
غير صحي
غير صحي جداً
خطير

10 Monitored Parameters

PM₂.₅
Fine Particulate Matter
µg/m³
25%
DM Formula Weight
الجسيمات الدقيقة
PM₁₀
Coarse Particulate Matter
µg/m³
14%
DM Formula Weight
الجسيمات الخشنة
CO₂
Carbon Dioxide
ppm
13%
DM Formula Weight
ثاني أكسيد الكربون
CO
Carbon Monoxide
ppm
8%
DM Formula Weight
أول أكسيد الكربون
VOCs
Volatile Organic Compounds
ppb
8%
DM Formula Weight
المركبات العضوية المتطايرة
HCHO
Formaldehyde
µg/m³
7%
DM Formula Weight
الفورمالديهايد
NO₂
Nitrogen Dioxide
µg/m³
7%
DM Formula Weight
ثاني أكسيد النيتروجين
O₃
Ozone
µg/m³
4%
DM Formula Weight
الأوزون
Temperature
Thermal Comfort
°C
6%
DM Formula Weight
درجة الحرارة
Humidity
Relative Humidity
%
8%
DM Formula Weight
الرطوبة النسبية

Ip = ((C − CL) / (CH − CL)) × (IH − IL) + IL

where C = measured concentration, CL/CH = category boundaries, IL/IH = index boundaries

Real-time EIAQI = max(all sub-indices) · Reporting EIAQI = Σ(Ip × Wp)

Source: DM-HSD-GU141-IAQI2, Section 7

Try the EIAQI Calculator

Move the sliders to see how your building's sensor readings translate into an EIAQI score in real time.

PM₂.₅8 µg/m³
0SI 33 · Good300
PM₁₀35 µg/m³
0SI 35 · Good400
CO₂520 ppm
400SI 30 · Good6000
CO1.5 ppm
0SI 19 · Good60
VOCs0.15 mg/m³
0SI 25 · Good3
HCHO30 µg/m³
0SI 30 · Good600
NO₂25 ppb
0SI 25 · Good400
O₃18 ppb
0SI 18 · Good400
Temperature23.5 °C
10SI 21 · Good45
Humidity48 %RH
10SI 20 · Good95

EIAQI Score

35
Good
0100200300500
Dominant PollutantPM₁₀
Weighted Report Score28

DM-HSD-GU141-IAQI2 · Real-Time Calculation

Naseem EIAQI Platform Capabilities

From Sensor Data to Municipality Report. Automatically.

Real-Time EIAQI Scoring

Every hour, Naseem calculates the EIAQI score for each zone in your building using the dominant pollutant method. When any parameter crosses into an unhealthy range, alerts fire immediately so you can act before the regulator does.

Hourly · Zone-Level · Dominant Pollutant Method

Automated Compliance Reports

8-hour, 24-hour, weekly, and monthly reports generated automatically using the weighted summation method from the DM guideline. Every report references DM-HSD-GU141-IAQI2, includes all sub-indices, and is ready for Municipality submission. Available in English and Arabic in a single PDF.

8hr · 24hr · Weekly · Monthly · PDF

View Sample Report

Tamper-Proof Audit Trail

Every sensor reading is SHA-256 hashed and chained to the previous entry, using the same cryptographic method found in financial audit systems. Data cannot be altered retroactively. Calibration records tracked per ISO 17025. Five-year retention. When the Municipality asks 'prove this reading is real,' you can.

SHA-256 · ISO 17025 · 5-Year Retention

Real-time alert monitoring

Real-time alert monitoring

Multi-Building Portfolio View

Manage 1 building or 100. Every zone in every building monitored from a single dashboard. Color-coded status at a glance. Compare buildings, identify problem zones, track improvement over time. Built for facility management companies overseeing entire portfolios.

Unlimited Zones · Building Comparison · Portfolio Dashboard

See the Platform in Action

Real screenshots from a live compliance monitoring session.

Live DashboardCalculation TransparencyCompliance ReportsSensor ManagementData IngestionArabic RTL

Real-time EIAQI scoring for every zone. The gauge shows the current score, parameter cards display individual readings with sub-indices, and the trend chart tracks compliance over time.

Your Path to Compliance

Whether you have sensors installed or starting from scratch.

Already Have Sensors

  1. 1

    Connect via API or CSV Upload

  2. 2

    Platform auto-maps your data format

  3. 3

    EIAQI scores calculated instantly

  4. 4

    Compliance reports generated automatically

  5. 5

    Submit to Dubai Municipality

Setup time: 1-2 days

Starting Fresh

  1. 1

    We recommend compatible IoT sensors

  2. 2

    Building installs sensors (any brand)

  3. 3

    Connect to Naseem EIAQI platform

  4. 4

    Monitoring, scoring, and reporting begins

  5. 5

    Full compliance from day one

Setup time: 1-2 weeks (including sensor installation)

From Sensors to Compliance in Three Steps

01

Connect

Connect any IoT sensor via REST API or upload CSV exports from your existing BMS. No proprietary hardware required. We normalize every data format to the DM standard automatically.

REST API · CSV Upload · Any Sensor Brand

02

Calculate

The exact EIAQI formula from DM-HSD-GU141-IAQI2 runs on every reading. Sub-indices per pollutant, health-impact weights, dominant pollutant identification, thermal comfort assessment. Hourly real-time scores plus 8-hour and 24-hour weighted reports.

10 Parameters · Weighted Summation · Real-Time

03

Report

Compliance reports generated in the format Dubai Municipality expects. Bilingual PDF with full sub-index breakdown, trend analysis, and recommendations. Download, print, or submit. Audit-ready from day one.

PDF · Bilingual · DM-Ready

Already Have Sensors Installed?

Naseem connects to any IoT sensor or BMS export. No hardware replacement, no vendor lock-in.

REST API

Any sensor that pushes data via HTTP. One authenticated endpoint, JSON payload. Real-time streaming or batch ingestion.

JSON · Bearer Auth · Any Brand

CSV / Excel Upload

Export from your BMS or sensor dashboard and drag-drop. We auto-map field names, convert units, and validate ranges.

CSV · XLSX · Up to 50,000 rows

Custom Integration

BACnet, Modbus, MQTT, or proprietary APIs. Our team implements custom connectors for enterprise deployments.

Enterprise · BACnet · Modbus · MQTT

No proprietary hardware. No vendor lock-in. Bring your own sensors and we normalize everything to the DM standard.

Technical Specifications

Monitored Parameters
10 (PM₂.₅, PM₁₀, CO₂, CO, VOCs, HCHO, NO₂, O₃, Temperature, Humidity)
EIAQI Categories
6 (Good → Hazardous)
Calculation Methods
Dominant Pollutant (real-time) + Weighted Summation (reporting)
Report Frequencies
Hourly, 8-hour, 24-hour, Weekly, Monthly
Data Retention
5 years minimum (per DM-HSD-GU141-IAQI2 Appendix 1)
Audit Trail
SHA-256 hash chain, tamper-proof logging
Sensor Compatibility
Any brand via REST API. CSV/Excel upload supported.
Calibration Tracking
ISO 17025 compliance monitoring with due-date alerts
Languages
English + Arabic (bilingual reports)
Compliance Standard
DM-HSD-GU141-IAQI2 V1, 14 February 2025
Supporting Legislation
Federal Law No. 5 of 2025, Law No. 3 of 2026
0-50Good
51-100Moderate
101-150USG
151-200Unhealthy
201-300Very Unhealthy
301-500Hazardous

Frequently Asked Questions

Your building's compliance deadline is approaching.

Start monitoring. Start scoring. Start reporting.

Start Your Building Assessment →

Questions? hello@naseem-eiaqi.com